Services & Solutions
Services & Solutions
Non contact safety switch IME2S
  • Non contact safety switch IME2S
  • Non contact safety switch IME2S
Non contact safety switch IME2S
  • Product details
Product Features

Sensor principle

Inductive type

Number of safe outputs

two

Housing diameter

M12

Trigger sensing distance Sn

8 mm 1)

Safe switching distance Sao

6.5 mm 1)

Safe cutoff distance Sar

12 mm 1)

Active sensor surface

one

Manipulation frequency

≤ 100 Hz


Safety technical parameters

Safety integrity level

SIL2 (IEC 61508)

category

Category 2 (ISO 13849-1)

Performance level

PL d (ISO 13849-1)

PFHD (hazard failure rate per hour)

6.0 x 10-8 (IEC 61508) 1)

TM (duration of operation)

20 years (ISO 13849-1)

structural style

Structural type 3 (ISO 14119-1)

Coding level of excitation element

Uncoded (EN ISO 14119)

Safer in error situations

There is at least one safety related semiconductor output terminal (OSSD) in the off state.